INPUT
RANGE
|
Counting - 0.1 C/sec to 3x105 C/sec
CURRENT 1x10-6 to 1x10-3 A |
LINEARITY
(LOG CONFORMITY) + 1% OF THE LINEAR
|
Full scale equivalent covering the
combined counting and current regions in the temperature range
of 20°to 30°C |
TEMPERATURE
COEFFICIENT
|
± 0.15%/°C maximum over 10° to 55°C |
CALIBRATION/TEST
|
2 fixed count rates, 2 fixed currents for calibration,
1 adjustable count rate, 1 adjustable current for trip testing, HV
trip test, test modes selected sequentially by front panel control |
RESPONSE
TIME CONSTANTS
|
| 10-4 to 10-3 Amperes |
<1 msec |
102 to 103 Counts/sec |
30 msec |
| 10-5 to 10-4 Amperes |
<2 msec |
101 to 102 Counts/sec |
0.3 sec |
| 10-6 to 10-5 Amperes |
2.5 msec |
100 to 101 Counts/sec |
3 sec |
| 104 to 105 Counts/sec |
15 msec |
10-1 to 100 Counts/sec |
30 sec |
| 103 to 104 Counts/sec |
20 msec |
|
|
|
OUTPUTS
|
| Remote Meter: 010 V
full scale |
Recorder: 01 V full
scale |
| Remote Meter: 01 mA
full scale |
Optional: 4.020 mA full
scale |
| Recorder: 00.1 V full
scale |
High Voltage: +300 to +800 VDC @2.6W |
|
BISTABLE
TRIPS
|
| High voltage |
Adjustable with |
| High power level |
+5 V logic level |
| Low power level |
and two form C |
| Period |
contacts per trip |
|
POWER
REQUIRED
|
117 VAC + 10% 50/60 Hz @ 1.0 A |